Power Generation/ Emergency Power FINALISTS

-- Consulting-Specifying Engineer, 6/28/2005

Bi-Fuel Standby Generator by Generac Power Systems
Bi-fuel standby generator has output ratings of 300 or 375 kW and can operate on up to 90% natural gas and 10% diesel fuel. Reduced consumption of diesel fuel under bi-fuel operation leads to significantly longer run times per tank of fuel, according to the manufacturer. The generator uses a method called combustion air gas integration, which introduces the proper amount of natural gas to the intake air prior to the turbocharger and takes advantage of the precision and response of the microprocessor controlling the mixture. As such, it responds instantly to an array of inputs, ensuring optimal performance regardless of the changing conditions. Additionally, knock sensors continually monitor internal combustion and detect the onset of engine knock before it occurs, thus preventing potential damage to internal components.
www.generac.com  

 

  STS2/PDU by Liebert
Static transfer switch provides an automatic, seamless transfer between a critical load and the outputs of two independent uninterruptible power supply systems in a dual-bus configuration. If the primary UPS fails, the switch automatically transfers the loads to the secondary UPS. The switch has triple-redundant logic, and each DSP controller is capable of working independently, in addition to monitoring the other two. If one malfunctions, the other two lock it out, and each controller has power feeds from both power supplies. All mechanical and electronic components are accessible from the front of the unit, allowing for more freedom in system design, ease of installation and service, and less floor space required for maintenance access. Additionally, the unit uses an internal CANBUS protocol for high-bandwidth communication.
www.liebert.com  
 
1600EP Series by Toshiba
Uninterruptible power systems are true on-line, double-conversion units that feature hot-swappable battery packs and cooling fans,  programmable front keypad, external battery connector and electronic power factor correction for 100% generator compatibility. Technical specifications include an input power factor greater than 0.95, input current THD less than 5%, input voltage window of 10% to 30%, input frequency window of 45 to 65 Hz and 0.85 output power factor. Overload capacity is 150% for 10 seconds, 125% for 10 minutes and 1,000% for one cycle.
www.tic.toshiba.com  

 

 

Email
Print
Reprint
Learn RSS

Talkback

We would love your feedback!

Post a comment

» VIEW ALL TALKBACK THREADS

Related Content

Related Content

 

By This Author

There are no other articles written by this author.



SPONSORED LINKS

 
Advertisement
Sponsored Links

More Content

  • Blogs

Blogs


Sorry, no blogs are active for this topic.

» VIEW ALL BLOGS RSS

Advertisements





NEWSLETTERS
Plug in and get the latest CSE news, trends and industry updates delivered directly to your inbox!

Green Scene
CSE Codes & Standards
CSE NewsWatch
CSE Fire and Life Safety Solutions
CSE Business of Engineering Management Report
CSE Electrical Solutions
CSE HVAC Solutions
Pure Power
CSE Product Showcase
©2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites

ADVERTISEMENT
You will be redirected to your destination in few seconds.